Back to top
Single Ended Shear Beam Load Cell

Single Ended Shear Beam Load Cell

Product Details:

  • Color Silver
  • Product Type Single Ended Shear Beam Load Cell
  • Voltage 15V DC Volt (v)
  • Usage Industrial
  • Material Stainless Steel
  • Output Analog Sensor
  • Type Single Ended Shear Beam Load Cell
  • Click to View more
X

Single Ended Shear Beam Load Cell Price And Quantity

  • 1 Piece

Single Ended Shear Beam Load Cell Product Specifications

  • Silver
  • Single Ended Shear Beam Load Cell
  • 15V DC Volt (v)
  • Single Ended Shear Beam Load Cell
  • Analog Sensor
  • Industrial
  • Stainless Steel
  • -35 to +65 Deg C Celsius (oC)

Single Ended Shear Beam Load Cell Trade Information

  • 100 Piece Per Week
  • 7 Days

Product Description



The Single Ended Shear Beam Load Cell is designed for industrial use, made of durable stainless steel in a sleek silver color. This analog sensor operates on a 15V DC voltage, suitable for a wide range of applications. With a temperature range of -35 to +65 degrees Celsius, this load cell is built to withstand harsh environmental conditions, providing reliable and accurate weight measurements.

Brand Keli
Model SQB
Type Single Ended Shear Beam
Capacity 3- 10 Ton
Material Stainless Steel
Ingress Protection IP68
Application Pallet Truck Scales
Features High Accuracy & Precision
Load Cell Certifications OIML
Output Sensitivity(FS) 3.0 +/- 0.003 mV/V
Combined Error <= +/- 0.02
Creep Error (30 minutes) <= +/- 0.02
Accuracy Class OIML R60 C3
Temperature Effect on Zero <= +/- 0.02
Temperature Effect on Output <= +/- 0.02
Zero balance +/- 1% FS
Maximum Safe Overload 150% FS
Ultimate Safe Overload 180% FS
Recommended Excitation Voltage 10 to 12V DC
Maximum Excitation Voltage 15V DC
Input Resistance 400 +/- 20 Ohm
Output Resistance 352 +/- 3 Ohm
Insulation resistance at 50V DC >= 5000 M Ohm
Compensated Temperature Range -10 to +40 Deg C
Operating Temperatue Range -35 to +65 Deg C
Load Cell Intervals (nLC)/Divisions 3000
Cable Length 5 Meter

 

FAQs of Single Ended Shear Beam Load Cell:


Q: What is the voltage requirement for this load cell?

A: The voltage requirement for this load cell is 15V DC.

Q: What is the temperature range for operating this load cell?

A: The operating temperature range for this load cell is -35 to +65 degrees Celsius.

Q: What material is this load cell made of?

A: This load cell is made of stainless steel.

Q: What type of load cell is this?

A: This is a Single Ended Shear Beam Load Cell.

Q: What is the color of this load cell?

A: This load cell comes in a silver color.